Your Cart

Free Shipping on Orders > $99.99 - *Some Exclusions May Apply

expand/collapse
(704) 979-7100 (0)
  • Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD
  • Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD
  • Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD
  • Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD
  • Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD
  • Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD
  • Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD
  • Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD

Bantam Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD

SKU#: 550-RM1440A

UPC#: 856804008083

60 Day Money Back Guarantee

100% Secure Shopping

SKU#: 550-RM1440A

UPC#:856804008083
$599.49

SKU#: 550-RM1440A

UPC#:856804008083
Option:

Same Day Shipping likely on orders placed in the next 00 hours 00 minutes 00 seconds.

Califonia Warning 65

California Prop 65 Warning

×
For CA Residents Only.
California Proposition 65 Warning

Proposition 65, officially the Safe Drinking Water and Toxic Enforcement Act of 1986, is a law that requires warnings be provided to California consumers when they might be exposed to chemicals identified by California as causing cancer or reproductive toxicity. The warnings are intended to help California consumers make informed decisions about their exposures to these chemicals from the products they use. The California Office of Environmental Health Hazard Assessment (OEHHA) administers the Proposition 65 program and publishes the listed chemicals, which includes more that 850 chemicals. In August 2016, OEHHA adopted new regulations, effective on August 30, 2018, which change the information required in Proposition 65 warnings.

• WARNING: Some cable, plastic, and metal products may contain chemicals known to the state of CA to cause cancer, birth defects, or other reproductive harm.

For further information, please visit www.P65Warnings.ca.gov

  • Description+
  • Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD

    The Bantam Clean Power Citadel is a complete, three-wire, bi-directional surge suppressor with harmonic attenuation, power factor correction and EMI/RFI filtering. Feature a full-color LCD digital power meter with a lab-quality 8/20 microsecond surge counter built-in. You will be able to see power metrics and surge counts in real-time! Choose either the RM1440 with a 120 Volt NEMA 5-15P input cordset or the RM2880 with a 230 Volt NEMA 6-15P input cordset.

    Our new flagship power conditioner, the Citadel by Bantam Clean Power, elevates your electronics' performance and protects them from the unknown. The Citadel features a full 12 amps of power protection to support critical connected devices. And with its all-new, custom designed information screen that includes a lab-quality surge counter, the Citadel informs you in real-time about your electrical power environment. The Citadel has a total of eight (8) outlets, two on the front panel and 6 on the rear panel. Unique to the Citadel RM1440 120 volt version are two IEC C10 outlets and two supplied IEC-to-NEMA 5-15R adapters. This gives you the flexibility to use IEC-only cordsets or power bricks (wall worts) without robbing space and blocking other outlets.

    Physical/Environmental

    • Enclosure Material: Molded ABS/PVC UL94-V0 industrial-grade plastic
    • Enclosure Dimensions: 11.75” x 8.25” x 1.75” (299mm x 210mm x 44.5mm)
    • Product Weight: 6 lbs. (2.72kg)
    • Storage Temp: (ambient): 40° to 80° F (4° to 27° Celsius)
    • Operating Temp: (ambient): -40° to 104° F (-20° to 40° Celsius)

    Installation

    • Desktop (vertical): Supplied with molded sturdy bolted stands
    • Desktop (horizontal): Supplied with soft feet and placement targets
    • Rack mount: Supplied with metal ears for mounting in 19-inch wide racks, may also mount vertically in zero-U rack configuration.
    • Wall Mount: Two keyholes provided on bottom side of enclosure for #10 panhead screws.
  • Features+
    • Provides complete surge suppression, EMI/RFI filtration, harmonic attenuation, power factor correction, energy storage and wave-shaping
    • 110-120 AC Volt, 12 amp Input and Output
    • Supports 1440 or 2880 watts of load
    • No moving parts, i.e. no fans, no relays, no switches
    • Patented filtration and conditioning on all three wires - line, neutral and ground for complete surge and noise protection
    • Never-fail, non-sacrifical component design.
    • Color LCD display shows Surge Counter, Volts, Amps, Power(Watts), Freq(Hz) and Power Factor in real-time
    • Unit may be mounted on a desktop either horizontally or vertically (feet supplied)
    • Unit may be mounted in a 19" two-post rack or cabinet (brackets supplied) - Unit is 1U (1.75") high.

    Physical/Environmental

    • Enclosure Material: Molded ABS/PVC UL94-V0 industrial-grade plastic
    • Enclosure Dimensions: 11.75” x 8.25” x 1.75” (299mm x 210mm x 44.5mm)
    • Product Weight: 6 lbs. (2.72kg)
    • Storage Temp: (ambient): 40° to 80° F (4° to 27° Celsius)
    • Operating Temp: (ambient): -40° to 104° F (-20° to 40° Celsius)

    Installation

    • Desktop (vertical): Supplied with molded sturdy bolted stands
    • Desktop (horizontal): Supplied with soft feet and placement targets
    • Rack mount: Supplied with metal ears for mounting in 19-inch wide racks, may also mount vertically in zero-U rack configuration.
    • Wall Mount: Two keyholes provided on bottom side of enclosure for #10 panhead screws.
  • Specs+
  • Model:

    RM1440A-US

    RM2880A-US

    Electrical Ratings

    Input Voltage:

    110 VAC, 60 Hz, cordset with NEMA 5-15P plug

    230 VAC 50 or 60 Hz, cordset with NEMA 6-15P plug

    Output Voltage:

    110-125 VAC, 60 Hz

    220 – 240 VAC 50 or 60 Hz

    Max. Input/Output Voltage:

    125 VAC, 60 Hz

    275 VAC, 50 or 60 Hz

    Input/Output Current (Max.):

    12 Amperes RMS

    12 amperes RMS

    VA Rating:

    1440 VA

    2880 VA

    Power Factor (PF):

    0.99

    Safety Standard(s):

    UL/IEC 62368-1

    Agency Listing(s):

    UL (file E521973)
    Performance Metrics

    Electrical Mode Protection:

    Patented series normal and common mode

    Harmonic Attenuation and Type:

    Up to 40% reduction of voltage and current noise up to 30 Mhz

    Power Factor Correction:

    Up to 30% improvement

    EMI/RFI Noise Attenuation:

    Over 20dB EMI/RFI suppression from 1Mhz to >20Mhz

    Electromagnetic Pulse (EMP)

    Blocks EMP current same as a surge, protecting line, neutral and ground paths

    Joule Rating (Surge):

    Series mode protection = unlimited joule rating

    Clamping Voltage (typical, closed circuit):

    At 120V AC, +/- 10V, neutral-ground +/- 10V

    At 230V AC, +/- 20V, neutral-ground +/- 20V

    Surge Suppression Residual Surge:

    Less than 1% of total surge current allowed to pass through to protective device

    Duty Cycle:

    Can indefinitely sustain and mitigate surges of 6000 Volts, 500 Amps occurring every 45 seconds, with less than 1% surge residual passing through Bantam to the protected device.

  • Reviews+
  • Citadel Power Conditioner with Rack, Table and Desk Mount, 8-outlets, LCD

    The Bantam Clean Power Citadel is a complete, three-wire, bi-directional surge suppressor with harmonic attenuation, power factor correction and EMI/RFI filtering. Feature a full-color LCD digital power meter with a lab-quality 8/20 microsecond surge counter built-in. You will be able to see power metrics and surge counts in real-time! Choose either the RM1440 with a 120 Volt NEMA 5-15P input cordset or the RM2880 with a 230 Volt NEMA 6-15P input cordset.

    Our new flagship power conditioner, the Citadel by Bantam Clean Power, elevates your electronics' performance and protects them from the unknown. The Citadel features a full 12 amps of power protection to support critical connected devices. And with its all-new, custom designed information screen that includes a lab-quality surge counter, the Citadel informs you in real-time about your electrical power environment. The Citadel has a total of eight (8) outlets, two on the front panel and 6 on the rear panel. Unique to the Citadel RM1440 120 volt version are two IEC C10 outlets and two supplied IEC-to-NEMA 5-15R adapters. This gives you the flexibility to use IEC-only cordsets or power bricks (wall worts) without robbing space and blocking other outlets.

    Physical/Environmental

    • Enclosure Material: Molded ABS/PVC UL94-V0 industrial-grade plastic
    • Enclosure Dimensions: 11.75” x 8.25” x 1.75” (299mm x 210mm x 44.5mm)
    • Product Weight: 6 lbs. (2.72kg)
    • Storage Temp: (ambient): 40° to 80° F (4° to 27° Celsius)
    • Operating Temp: (ambient): -40° to 104° F (-20° to 40° Celsius)

    Installation

    • Desktop (vertical): Supplied with molded sturdy bolted stands
    • Desktop (horizontal): Supplied with soft feet and placement targets
    • Rack mount: Supplied with metal ears for mounting in 19-inch wide racks, may also mount vertically in zero-U rack configuration.
    • Wall Mount: Two keyholes provided on bottom side of enclosure for #10 panhead screws.
    • Provides complete surge suppression, EMI/RFI filtration, harmonic attenuation, power factor correction, energy storage and wave-shaping
    • 110-120 AC Volt, 12 amp Input and Output
    • Supports 1440 or 2880 watts of load
    • No moving parts, i.e. no fans, no relays, no switches
    • Patented filtration and conditioning on all three wires - line, neutral and ground for complete surge and noise protection
    • Never-fail, non-sacrifical component design.
    • Color LCD display shows Surge Counter, Volts, Amps, Power(Watts), Freq(Hz) and Power Factor in real-time
    • Unit may be mounted on a desktop either horizontally or vertically (feet supplied)
    • Unit may be mounted in a 19" two-post rack or cabinet (brackets supplied) - Unit is 1U (1.75") high.

    Physical/Environmental

    • Enclosure Material: Molded ABS/PVC UL94-V0 industrial-grade plastic
    • Enclosure Dimensions: 11.75” x 8.25” x 1.75” (299mm x 210mm x 44.5mm)
    • Product Weight: 6 lbs. (2.72kg)
    • Storage Temp: (ambient): 40° to 80° F (4° to 27° Celsius)
    • Operating Temp: (ambient): -40° to 104° F (-20° to 40° Celsius)

    Installation

    • Desktop (vertical): Supplied with molded sturdy bolted stands
    • Desktop (horizontal): Supplied with soft feet and placement targets
    • Rack mount: Supplied with metal ears for mounting in 19-inch wide racks, may also mount vertically in zero-U rack configuration.
    • Wall Mount: Two keyholes provided on bottom side of enclosure for #10 panhead screws.

    Model:

    RM1440A-US

    RM2880A-US

    Electrical Ratings

    Input Voltage:

    110 VAC, 60 Hz, cordset with NEMA 5-15P plug

    230 VAC 50 or 60 Hz, cordset with NEMA 6-15P plug

    Output Voltage:

    110-125 VAC, 60 Hz

    220 – 240 VAC 50 or 60 Hz

    Max. Input/Output Voltage:

    125 VAC, 60 Hz

    275 VAC, 50 or 60 Hz

    Input/Output Current (Max.):

    12 Amperes RMS

    12 amperes RMS

    VA Rating:

    1440 VA

    2880 VA

    Power Factor (PF):

    0.99

    Safety Standard(s):

    UL/IEC 62368-1

    Agency Listing(s):

    UL (file E521973)
    Performance Metrics

    Electrical Mode Protection:

    Patented series normal and common mode

    Harmonic Attenuation and Type:

    Up to 40% reduction of voltage and current noise up to 30 Mhz

    Power Factor Correction:

    Up to 30% improvement

    EMI/RFI Noise Attenuation:

    Over 20dB EMI/RFI suppression from 1Mhz to >20Mhz

    Electromagnetic Pulse (EMP)

    Blocks EMP current same as a surge, protecting line, neutral and ground paths

    Joule Rating (Surge):

    Series mode protection = unlimited joule rating

    Clamping Voltage (typical, closed circuit):

    At 120V AC, +/- 10V, neutral-ground +/- 10V

    At 230V AC, +/- 20V, neutral-ground +/- 20V

    Surge Suppression Residual Surge:

    Less than 1% of total surge current allowed to pass through to protective device

    Duty Cycle:

    Can indefinitely sustain and mitigate surges of 6000 Volts, 500 Amps occurring every 45 seconds, with less than 1% surge residual passing through Bantam to the protected device.

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
Open Google Reviews for our website ×