Klein Tools ET310 Digital Circuit Breaker Finder with GFCI Outlet Tester
Same Day Shipping likely on orders placed in the next 00 hours 00 minutes 00 seconds.
California Prop 65 Warning
For CA Residents Only.
California Proposition 65 Warning
Proposition 65, officially the Safe Drinking Water and Toxic Enforcement Act of 1986, is a law that requires warnings be provided to California consumers when they might be exposed to chemicals identified by California as causing cancer or reproductive toxicity. The warnings are intended to help California consumers make informed decisions about their exposures to these chemicals from the products they use. The California Office of Environmental Health Hazard Assessment (OEHHA) administers the Proposition 65 program and publishes the listed chemicals, which includes more that 850 chemicals. In August 2016, OEHHA adopted new regulations, effective on August 30, 2018, which change the information required in Proposition 65 warnings.
• WARNING: Some cable, plastic, and metal products may contain chemicals known to the state of CA to cause cancer, birth defects, or other reproductive harm.
For further information, please visit www.P65Warnings.ca.gov
- Description+
- Features+
- Quickly and accurately locate the correct circuit breaker in a panel corresponding to the circuit to which an electrical outlet or fixture is connected
- Tester consists of two parts: a Transmitter, connected to the electrical outlet or fixture and a Receiver, used to scan the panel to locate the correct breaker
- Receiver delivers clear visual and audible indications when the correct breaker has been located
- Operates on 90-120V AC circuits
- Transmitter incorporates a GFCI outlet tester to inspect the wiring condition at the electrical outlet and test GFCI devices
- Transmitter docks in the Receiver for convenient storage as a single item when tester is not is use
- Transmitter incorporates a three-pin plug for connecting to North-American-style grounded electrical outlets.
- The transmitter may be connected to other electrical fixtures using optional accessories which are sold separately (Cat. No. 69411)
- Receiver powers off automatically after approximately three minutes of non-use to conserve battery life
- Transmitter is powered by the circuit when connected to the electrical outlet or fixture
- Low battery indicator
- Easily accessible battery compartment. Uses one 9V battery in receiver only; Transmitter does not require a battery
- Built to withstand a 6.6-Foot (2 m) drop
- CAT II 120V safety rating
- Measurement Category II is applicable to test and measuring circuits connected directly to utilization points (socket outlets and similar points) of the low-voltage MAINS installation
- Includes Transmitter, Receiver, user manual, and 9V battery (for Receiver)
- Specs+
- Type: Electronic Tester
- Application: Locate Circuit Breakers in Panel, Test GFCI Devices
- Special Features: Transmitter docks in Receiver Transmitter integrated GFCI outlet tester in receiver
- Overall Length: 10.96'' (278mm) (With Transmitter docked in Receiver)
- Overall Height: 2.16'' (55mm) (With Transmitter docked in Receiver)
- Overall Width: 1.39'' (35mm) (With Transmitter docked in Receiver)
- Material: PC & PC-ABS housing and electronic components
- Standard: CATII 120V
- Included: Includes Transmitter, Receiver, user manual, and 9V battery for Receiver
- Weight: 7.2 oz. (204 g)
- UPC: 092644692406
- Package Contents+
- Reviews+
- Quickly and accurately locate the correct circuit breaker in a panel corresponding to the circuit to which an electrical outlet or fixture is connected
- Tester consists of two parts: a Transmitter, connected to the electrical outlet or fixture and a Receiver, used to scan the panel to locate the correct breaker
- Receiver delivers clear visual and audible indications when the correct breaker has been located
- Operates on 90-120V AC circuits
- Transmitter incorporates a GFCI outlet tester to inspect the wiring condition at the electrical outlet and test GFCI devices
- Transmitter docks in the Receiver for convenient storage as a single item when tester is not is use
- Transmitter incorporates a three-pin plug for connecting to North-American-style grounded electrical outlets.
- The transmitter may be connected to other electrical fixtures using optional accessories which are sold separately (Cat. No. 69411)
- Receiver powers off automatically after approximately three minutes of non-use to conserve battery life
- Transmitter is powered by the circuit when connected to the electrical outlet or fixture
- Low battery indicator
- Easily accessible battery compartment. Uses one 9V battery in receiver only; Transmitter does not require a battery
- Built to withstand a 6.6-Foot (2 m) drop
- CAT II 120V safety rating
- Measurement Category II is applicable to test and measuring circuits connected directly to utilization points (socket outlets and similar points) of the low-voltage MAINS installation
- Includes Transmitter, Receiver, user manual, and 9V battery (for Receiver)
- Type: Electronic Tester
- Application: Locate Circuit Breakers in Panel, Test GFCI Devices
- Special Features: Transmitter docks in Receiver Transmitter integrated GFCI outlet tester in receiver
- Overall Length: 10.96'' (278mm) (With Transmitter docked in Receiver)
- Overall Height: 2.16'' (55mm) (With Transmitter docked in Receiver)
- Overall Width: 1.39'' (35mm) (With Transmitter docked in Receiver)
- Material: PC & PC-ABS housing and electronic components
- Standard: CATII 120V
- Included: Includes Transmitter, Receiver, user manual, and 9V battery for Receiver
- Weight: 7.2 oz. (204 g)
- UPC: 092644692406